Conductor: Solid or Stranded Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 450/750 V
Size: 1.5 mm² up to 400 mm²
Reference Standard: TIS 11 Part 3-2553, Table 1
Conductor: Stranded Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 450/750 V
Size: 1.5 mm² up to 240 mm²
Reference Standard: TIS 11 Part 3-2553, Table 3
Conductor: Solid Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/500 V
Size: 0.5 mm² up to 1 mm²
Reference Standard: TIS 11 Part 3-2553, Table 5
Conductor: Stranded Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/500 V
Size: 0.5 mm² up to 1 mm²
Reference Standard: TIS 11 Part 3-2553, Table 7
Conductor: Solid Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/500 V
Size: 0.5 mm² up to 2.5 mm²
Reference Standard: TIS 11 Part 3-2553, Table 9
Conductor: Stranded Annealed Copper
Insulation: Color-Coded Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/500 V
Size: 0.5 mm² up to 2.5 mm²
Reference Standard: TIS 11 Part 3-2553, Table 11
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/300 V
Size: 0.5 mm² and 0.75 mm²
Reference Standard: TIS 11 Part 5-2553, Table 7
Conductor: Stranded Annealed Copper
Insulation: Blue and Brown Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
3 Cores: Blue, Brown, and Green/Yellow
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/300 V
Size: 0.5 mm² and 0.75 mm²
Reference Standard: TIS 11 Part 5-2553, Table 7
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/500 V
Size: 0.75 mm² and 1 mm²
Reference Standard: TIS 11 Part 5-2553, Table 9
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
3 Cores: Blue, Brown, and Green/Yellow
4 Cores: Brown, Black, Grey, and Green/Yellow
5 Cores: Blue, Brown, Black, Grey, and Green/Yellow
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 70˚C
Rated Voltage: 300/500 V
Size: 0.75 mm² up to 2.5 mm²
Reference Standard: TIS 11 Part 5-2553, Table 9
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/300 V
Size: 0.5 mm² and 0.75 mm²
Reference Standard: TIS 11 Part 5-2553, Table 11
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
3 Cores: Blue, Brown, and Green/Yellow
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/300 V
Size: 0.5 mm² and 0.75 mm²
Reference Standard: TIS 11 Part 5-2553, Table 11
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/500 V
Size: 0.75 mm² and 1 mm²
Reference Standard: TIS 11 Part 5-2553, Table 13
Conductor: Stranded Annealed Copper
Insulation: Polyvinyl Chloride (PVC)
2 Cores: Blue and Brown
3 Cores: Blue, Brown, and Green/Yellow
4 Cores: Brown, Black, Grey, and Green/Yellow
5 Cores: Blue, Brown, Black, Grey, and Green/Yellow
Sheath: Black Polyvinyl Chloride (PVC)
Maximum Conductor Temperature: 90˚C
Rated Voltage: 300/500 V
Size: 0.75 mm² up to 2.5 mm²
Reference Standard: TIS 11 Part 5-2553, Table 13